Step 1 of 6: Position the  CMS™ next to the OSD™.

CMS unit shown on left; OSD Filter shown on right

Step 2 of 6: Connect black plastic tube from CMS™ pump to inlet connection on top of OSD™.

Tube from CMS to be connect to OSD

Step 3 of 6: Connect fluid supply line to CMS™ inlet located on back side of CMS™:

bulletBe careful not to rotate the connection on the CMS™ inlet port.
bulletArrow on CMS™ inlet port must point UP.

CMS supply line inlet

Step 4 of 6: Connect discharge hose to OSD™ Clean Water outlet located on back side of OSD™ and run to drain.

OSD Clean Water Outlet

Step 5 of 6: Connect CMS™ 115 volt power cord to 115/1/60 outlet.

Step 6 of 6: Drain decanted oil weekly into customer supplied bucket.