Field Results - CNC Coolant Filtration
Clean
& Clear's OSD™ technology removes contaminants from CNC coolant without
chemical change to the coolant. With fully filtered coolant on the
left and unfiltered coolant on the right, this photo shows the progression of
CNC coolant through various stages of the the Clean & Clear OSD™
filtration process (the middle two bottles show coolant after partial
filtration).
Below are descriptions of two field tests conducted of Clean & Clear's
OSD™ technology in CNC Coolant Filtration applications. The first test
shown was done on the Clean & Clear OSD™ installation at Suburban
Manufacturing; the second test shown was done on the Clean & Clear OSD™
installation at Waterous Company.
Return to Industrial Fluids Filtration Systems
Suburban Manufacturing
Background. Suburban
Manufacturing is a recognized leader in heating and water heating equipment
for the recreational vehicle industry. It also offers products to the
residential and commercial markets. Suburban installed
Clean & Clear OSD™ CNC Coolant Filtration System to remove contaminants
from their CNC coolant, thus making the coolant suitable for reuse.
Results. Independent tests of
Suburban's Clean & Clear OSD™ system were performed by Hangsterfer's
Laboratories, Inc. The results of Hangsterfer's before and after
testing of Suburban's CNC Coolant are shown below:
| Test |
Sample - BEFORE Filtration |
Sample - AFTER Filtration |
| Lab Report Number |
020122 |
020123 |
| Description |
Non-Filtered Used Coolant |
Filtrated Used Coolant |
Refractometer
Shaken
Decanted |
Cloudy - 8
Cloudy - 8 |
Cloudy - 7
Cloudy - 7 |
| Appearance |
Milky |
Milky |
| Odor |
Mild |
Mild |
| Foam |
High |
High |
| pH |
8.9 |
8.9 |
Tramp Oil
percent by volume |
3 |
Ring |
Cream Layer
percent by volume |
Ring |
1 |
Solids
percent by volume |
Trace |
Trace |
Acid Split (Tramp Oil + Coolant)
percent by volume |
12.8 |
7.2 |
Actual Coolant Concentration
percent by volume |
9.8 |
6.7 |
Total Dissolved Solids
milligrams/liter |
3240 |
1610 |
Conductivity
microseimens |
4880 |
2420 |
| Bacteria Aerobic |
10*3 |
10*4 |
| Fungus |
Nil |
Nil |
| Samples |
 |
 |
| Comments |
Conclusion: This sample is in fair condition.
The concentration and pH are good. There is too much tramp
oil. Conductivity and TDS are relatively high, suggesting
contamination.
Recommendation: Remove the tramp oil. Continue with proper
maintenance. |
Conclusion: This sample is in good condition.
The concentration and pH are good.
Recommendation: Continue with proper maintenance. |
Top
Waterous Company
Background. Waterous
Company is the leading manufacturer in fire pump technology providing the
highest-quality fire pumps, transmissions and CAFSystems™. Waterous installed
Clean & Clear OSD™ CNC Coolant Filtration System to remove contaminants
from their CNC coolant, thus making the coolant suitable for reuse.
Results. Independent tests of
Waterous' Clean & Clear OSD™ system were performed by Hangsterfer's
Laboratories, Inc. The results of Hangsterfer's before and after
testing of Waterous' CNC Coolant are shown below:
| Test |
Sample - BEFORE Filtration |
Sample - AFTER Filtration |
| Lab Report Number |
020048 |
020049 |
| Description |
Non-Filtered Used Coolant |
Filtrated Used Coolant |
Refractometer
Shaken
Decanted |
Clear - 4
Clear - 4 |
Clear - 4
Clear - 4 |
| Appearance |
Cloudy |
Cloudy |
| Odor |
Mild |
Mild |
| Foam |
High |
Low |
| pH |
8.3 |
8.3 |
Tramp Oil
percent by volume |
Nil |
Nil |
Cream Layer
percent by volume |
Nil |
Nil |
Solids
percent by volume |
> 1.00% |
Nil |
Acid Split (Tramp Oil + Coolant)
percent by volume |
Nil |
Nil |
Actual Coolant Concentration
percent by volume |
10.0 |
10.0 |
Total Dissolved Solids
milligrams/liter |
1770 |
1700 |
Conductivity
microseimens |
2670 |
2570 |
| Bacteria Aerobic |
Nil |
Nil |
| Fungus |
Nil |
Nil |
| Samples |
 |
 |
| Comments |
Conclusion: This sample is in good condition.
The concentration and pH are both within the desired ranges.
Recommendation: Refer to report 020049 |
Conclusion: This sample is in good condition.
Recommendation: It appears that the filtration has worked
without chemical change to the coolant. |